Product Series

Contact Information

Company Address  No. 3716 Qingdao Road, Huaiyin District, Jinan City, Shandong Province, Unit 1801, China Construction Jinxiu Plaza.

Production base  Juye Chemical Industry Park, Heze City, Shandong Province.

Nanjing Branch Company  Room B2304, Nanjing University of Technology (Dingjiaqiao Campus), No. 5 Xinmofanma Road, Gulou District, Nanjing City, Jiangsu Province.

Phone  +86-531-88986356 

Phone +86-15562623709 
Email sdprio@sdprio.com

Detailed introduction

Product Performance

PO-511 The reverse osmosis cleaning agent is an alkaline, composite liquid formulation suitable for... CA And TFC Chemical cleaning of reverse osmosis membrane elements in this series causes no damage to the RO membranes. It exhibits strong permeation and solubilization capabilities against sludge, organic matter, oils, microorganisms, viscous substances, and non-acid-soluble materials, and does not generate secondary sedimentation or contamination during the cleaning process.

 

Technical indicators.

Project

Indicator

Appearance

Colorless, transparent liquid

pH (1% aqueous solution)

≥10.0

Density (20℃), g/cm³

≥1.05

Minimum storage temperature Celsius

-5

 

Instructions for use --- Note: The acidic cleaner and the alkaline cleaner are used in the same way.

Dosage point: The cleaning agent should be used in conjunction with the membrane cleaning equipment provided by the membrane system manufacturer. If such equipment is not available, please contact Prio's technical engineers to manufacture or obtain membrane cleaning equipment.

Dosage: The technical engineers from Prio will determine the optimal dosage based on the actual conditions of your system, typically as a percentage of the total volume of the cleaning system liquid. 2-5%, The entire system includes a cleaning tank, connecting pipelines, a filter, a pressure vessel, and a membrane.

Dilution: The cleaning agent must be diluted in the cleaning tank before being introduced into the membrane system. It is recommended to dilute it to a mass concentration of... 2%-5% (Acidic cleaning agent adjusted to 2-3 Alkaline cleaning agent ph Adjust to 10-11 , use R0 Prepare cleaning solution for water production )

Cleaning instructions:

1 1. Inspect and connect the cleaning circuit: The cleaning tank, pipelines, and security filter have been properly connected. Clean them thoroughly with demineralized water, performing at least two complete cleaning cycles. If necessary, install a new filter cartridge into the security filter. During cleaning, circulate the prepared cleaning solution at low pressure and high flow rate on the concentrate side of the membrane; at this stage, the membrane elements remain installed inside the pressure vessel.

2 Fill the cleaning tank to half its volume with reverse-osmosis permeate or demineralized water. Slowly add the pre-calculated amount of cleaning agent into the cleaning tank, and mix thoroughly. Ideally, maintain the temperature of the cleaning solution within... 30 Around ℃.

3 According to the cleaning circuit, start the cleaning pump and begin the cleaning process. Initially, the effluent will flow out. RO The membrane cleaning solution should be drained from the system, with a volume approximately equal to that of the cleaning tank. 10%-20%, The cleaning flow rate and velocity should follow the recommended values provided by the membrane manufacturer or system supplier. The cleaning duration depends on the degree of fouling; generally, 8-12 An hour.

Related Downloads

Application scenarios

8
7
6
5
4
3
2
1

Get a quote

Please fill in your contact information and specify your requirements, and we’ll arrange for a specialist to get in touch with you!

  • How many products do you need?
  • What else do you need to know?
Submit